CE Approved Class B High Quality Autoclave Steam Sterilizer
Steam Sterilizer is mainly used for the sterilization, leak test, and washing of ampoule, syrup, and IV solution with small capacity. It adopts pressure steam as sterilizing medium to achieve uniform sterilization between 105℃~127℃. This sterilizer adopts the heating mode of displacement and exhaust from multi-points to ensure the the elimination of cold air in the chamber, uniform and rapid heating and eliminate the dead corner caused by the existing cold air. Leak test by vacuum and color water is adopted to improve the detection rate of waste after sterilization, meanwhile provides the documents system that meets 2010 version GMP requirement.
Sterilizer features:
Specifications:
Model |
MD-0.36 |
Door number |
Double door |
Door type |
Motorized Hinge Door |
Chamber volume |
360L |
Chamber Size |
600*600*1000mm |
Overall Size |
1350*1800*1340mm |
Net Weight |
800kg |
Steam |
25Kg/cycle |
Water |
60Kg/cycle |
Power(KVA) |
2KVA |
Sterilization temperature rage |
105°C to 134°C |
Sterilization time rage |
0---99 minutes |
Vacuum times |
0---9 times |
Drying time |
0---99 minutes |
Test programmes |
heating, Bowie & Dick, vacuum test |
Working programs |
Multiple customizable programs for textiles, instruments, rubbers, culture medium and liquids in unsealed bottles. |
APPLICATION :
1. Hospital CSSD
2. Operating room
3. Medical centers
4. Outpatient care centers
5. Medical clinics
6. Emergency rooms
Keyboard and printer:
Multifunctional keyboard: Interface through virtual keyboard on the Touch Screen to select
the process parameters and enter cycles programming data.
The command enables the cycle parameters configuration through password within the safety
range defined in the design.
Printer: The printer can be optionally installed on the frontal panel of the sterilizer and it enables
to document the process by registering the time of the beginning of the process, time, temperature
and pressure data of the inner chamber during the sterilization process, beginning of the cycle,
cycle phases, beginning and end of exposure phase and indication of signature place of operator
and supervisor’s unit.
The printer consists of a plastic body and a lid that covers the paper reel. It has a thermal print
mechanism and uses paper reel to print.
Recorder: optionally installed in the sterilizer front panel. High quality graphic recorder for obtaining
data such as: time, temperature and pressure. It presents configurable channels which allow the
visualization of measures, scales or graphic bars. The recorder may be operated through operation keys or using a PC through a Compact Flash card or serial port.
Contact Person: Ms. Juliet
Tel: + 86 15466171
Fax: +86-512-58592400