Product Details:
Payment & Shipping Terms:
|
Application: | Clinics, Laboratories | Chamber Volume: | 35L |
---|---|---|---|
Feature: | Drying System | Controller: | Micro-computer Control Panel |
Material: | SS304 Or 316L | Safety System: | Door Safety Lock System |
High Light: | 35L Portable Steam Sterilizer,SS304 Portable Steam Sterilizer,304Ti Medical Steam Sterilizer |
Portable Pressure Steam Sterilizer Medical Steam Sterilization Equipment
Quick detail
Features:
Parameters
Product name | Autoclave Sterilization Hospital Steam Disinfectant Machine |
Sterilization roon size(cm) | Φ31.9*61.5 |
Outline dimension(cm) | 94*59*57.5 |
Product form | Desktop |
Heating mode | electrical heating |
Power supply | AC220V,50Hz |
Sterilizing chamber material | The sterilizing chamber is 304 anticorrosive stainless steel with thickness ≥ 3mm, safety door thickness ≥ 15mm, hydraulic test ≥ 0.8mpa. which exceeds the national standard of YY0646-2008 design. |
Outer box material | Carbon steel (1.5mm thick) baking powder |
Work environment | 0-50℃ |
Working pressure | -80kpa~200kpa |
Sterilization humidity | ≥80% |
Maximum pressure resistance | -120kpa~260kpa |
Sterilization temperature | 121℃-135℃ adjustable |
Vacuum mode | Three pre-vacuum to ensure faster heating, sterilization more thorough. |
Over voltage protection program | When the sterilizing chamber pressure reaches 220 ±5kPakPa, there are cues and automatic pressure relief. |
Pressure sensor |
The inner pressure sensor automatically detects the pressure inside the cavity to ensure the accuracy and efficiency of the pressure. |
Temperature sensor | The built-in temperature sensor automatically detects the temperature inside the cavity to ensure that the temperature in the cavity is within the accurate range of ±3 ℃. |
Sterilization mode | Bare equipment, cotton yarn, wrapping equipment, plastic and rubber equipment products, the default working temperature is 135 ℃. |
Sterilization time at 135 ℃ |
36 minutes(Preheat 12 minutes, vacuum 4 minutes, sterilization 4 minutes, dry 16 minutes) |
Sterilization time at 122 ℃ | 56 minutes(Preheat 8 minutes, vacuum 4 minutes, sterilize 5-20 minutes, dry 20 minutes) |
Alarm system | High and low temperature alarm system |
Category | Class II medical devices |
Model chart
Order No. |
Chamber |
Dimensions (mm) |
Package Dimensions (mm) |
NW/GW |
Power |
VT-35HG |
35L(φ318*450mm) |
600*410*1030 |
730*500*1170 |
77/96Kg |
2.5KW/AC220V,50Hz |
VT-50HG |
50L(φ340*550mm) |
650*410*1140 |
730*500*1290 |
83/102Kg |
3KW/AC220V,50Hz |
VT-75HG |
75L(φ400*600mm) |
690*470*1140 |
760*550*1290 |
98/120Kg |
4.5KW/AC220V,50Hz |
VT-100HG |
100L(φ440*650mm) |
730*510*1270 |
820*600*1380 |
110/135Kg |
4.5KW/AC220V,50Hz |
Applications
Vertical sterilizer for clinics, laboratories, research institutes, hospitals
Contact Person: Ms. Juliet
Tel: + 86 15466171