Product Details:
Payment & Shipping Terms:
|
Configuration: | Floor-Standing | Chamber Volume: | 1.5m³ To 8m³ |
---|---|---|---|
Door Type: | Motorized Hinge Door | Control System: | Touch Screen + Plc System |
Sterilization Procedures: | Steam | Application: | CSSD |
Highlight: | Medical Waste Autoclave,Steam Autoclave Sterilizer |
Floor standing Large Waste Autoclaves With Temperature Sensors For CSSD
Key Feature
Functions
Controller Software
Sensors And Transducers
Chamber Vent Temperature
Load Temperature (Flexible Probe for liquid waste)
Chamber
Jacket
Water (Optional)
Compressed Air (Optional)
Steam (Optional, if fitted)
Model Chart
Model | Chamber Size | Overall Size | Net Weight | Steam | Water | Power |
W*H*D mm | W*H*D mm | Kg | Kg/cycle | Kg/cycle | KVA | |
MD-1.5 | 680*1180*1870 | 1600*2000*2210 | 2150 | 50 | 150 | 4.5 |
MD-2.0 | 1000*1200*1700 | 2000*2000*2040 | 2400 | 60 | 200 | 4.5 |
MD-3.0 | 1000*1500*2000 | 2000*2200*2340 | 2950 | 90 | 300 | 5 |
MD-4.0 | 1000*1500*2670 | 2000*2200*3010 | 3600 | 120 | 400 | 6 |
MD-5.0 | 1000*1500*3340 | 2000*2200*3680 | 4500 | 150 | 500 | 8 |
MD-6.0 | 1000*1500*4000 | 2000*2200*4340 | 5300 | 180 | 600 | 8 |
MD-8.0 | 1000*1500*5340 | 2000*2200*5680 | 6900 | 240 | 800 | 12 |
Materials
Chamber | STEEL |
|
304 L stainless steel | STANDARD | |
316 L stainless steel |
| |
Jacket | STEEL |
|
304 L stainless steel | STANDARD | |
316 L stainless steel |
| |
Door internal side | STEEL |
|
304 L stainless steel | STANDARD | |
316 L stainless steel |
|
Features And Benefits
1. No Pre-Treatment Handling Risks
The System utilizes autoclavable carts that can eliminate employee handling of untreated waste from point of generation to final disposal.
2. Capital Cost
The Sterilizer is by far the least expensive medical waste treatment system available.
3. Sterilizers Available For Any Size Facility
Units are capable of treating 100 to 1,125 lbs. or more per cycle.
4. Least Complicated To Operate
Some companies actually require the hospital to send engineers to the factory for training. The Sterilizers require nothing more than a brief in-service training period at the site following installation.
5. Simple To Install
The Sterilizers are usually installed by hospital personnel, or local equipment contractors.
6. Equipment Design Unchanged
There is no need to be concerned that the system will soon be out of date, making it difficult to obtain parts and repairs.
7. Utility Consumption
Most Medpharm Sterilizers use existing low cost readily available hospital steam supply.
8. Steam Sterilization Vs Disinfection
Because of the National and World focus on the spread of infectious disease, the eradication of all microbial life in the waste stream is imperative. The Sterilization process is the best assurance the hospital can have for proper spore kill.
Brochure load down from here
Medpharm medical large steam autoclave brochure.pdf
Contact Person: Ms. Juliet
Tel: + 86 15466171
Fax: +86-512-58592400