Product Details:
Payment & Shipping Terms:
|
Door Type: | Motorized Hinge Door.Two Doors | Chamber And Jacket Material: | SS316L/ SS304 |
---|---|---|---|
Chamber Volume: | 600 Liter | Steam Supply: | Built In Steam Generator |
Display Panel: | Color Touch Screen | Safe Feature: | Safety Door Design |
High Light: | Plasma Sterilization Equipment,Sterilization Using Autoclave |
Double Door Safety Lock Pharmaceutical Autoclave With Colored Touch Screen
Key Features
1. Rectangle chamber to save the space
2. Motorized hinge door, the sterilizer equipped with double doors
3. Chamber is made of AISI 316L ,the jacket and piping is made of SS304
4. Built -in steam generator to supply steam, it is made of 304 stainless steel
5. High capacity and strong special post vacuum drying function
6. 5.7 inch color touch screen
7. User friendly control system
8. Ideal steam sterilizers for dealing with rubber plugs and aluminum caps in pharmaceutical industry
Specifications
Model |
MDR-0.6 |
Chamber volume |
600 liters |
Chamber Size |
610*910*1170mm |
Overall Size |
1350*1900*1510mm |
Net Weight |
1250kg |
Steam |
30Kg/cycle |
Water |
60Kg/cycle |
Power(KVA) |
3KVA+36Kw for steam generator |
Sterilization temperature rage |
105°C to 134°C |
Sterilization time rage |
0---99 minutes |
Vacuum times |
0---9 times |
Drying time |
0---99 minutes |
Testing cylces |
Bowie & Dick test, vacuum test |
Water pressure |
0.15----0.3MPa |
Compressed air pressure |
0.5---0.8MPa |
Steam pressure |
0.4---0.7MPa |
Safety Design
Chamber Design |
The sterilization chamber is constructed of 316L stainless steel and is polished to a minimum 20 Ra internal finish |
The chamber is a fully jacketed construction using 304 stainless steel. |
|
The chamber is covered with rock wool |
|
Door System |
Door(s) are constructed of 316L stainless steel and are polished to a minimum 20Ra on the chamber interface side |
For double door units, pass-through door operation is utilized to prevent cross-contamination from load to unload sides of the sterilizer. In the event of an aborted cycle, the load is returned to the loading side. |
|
Door Safety Interlocks |
Door limit switch to determine closed position of the door |
Pneumatic interlocks to prevent the chamber or door seal from being pressurized with air while the door is open. |
|
Mechanical lock on the door to prevent opening during a cycle |
|
Physical mechanical stops for the door in the event of a catastrophic over pressure within the chamber. |
|
Two (2) Electrical interlocks to prevent the chamber from being opened while chamber is under pressure. |
|
Pass-through design to prevent cross- contamination from load to unload sides of the sterilizer. |
Quality Standards