Product Details:
Payment & Shipping Terms:
|
Model Name: | Laboratory Autoclave | Used For: | Laboratory |
---|---|---|---|
Sizes: | 800 Liters | Door Type: | Hinge Motor Door |
Stainless Steel For: | Chamber, Jacket,pipes And Valves | Sterilization Media: | Saturated Steam |
Sterilization Temperature: | 105°C To 134°C | Advantages: | No Pollution Generated To Environment |
High Pressure Sterilization Autoclave With Low Power Comsuption For Laboratory
Specification
Main Parameters
Model | Chamber Size | Overall Size | Net Weight | Steam | Water | Power |
W*H*D mm | W*H*D mm | Kg | Kg/cycle | Kg/cycle | KVA | |
MD-0.24 | 600*600*670 | 1500*1800*1010 | 700 | 20 | 30 | 2 |
MD-0.36 | 600*600*1000 | 1500*1800*1340 | 800 | 25 | 40 | 2 |
MD-0.6 | 610*910*1170 | 1500*1900*1510 | 1250 | 30 | 60 | 3 |
MD-0.8 | 610*910*1450 | 1500*1900*1790 | 1400 | 35 | 80 | 3 |
MD-1.0 | 680*1180*1250 | 1600*2000*1590 | 1550 | 40 | 100 | 4 |
MD-1.2 | 680*1180*1500 | 1600*2000*1840 | 1950 | 45 | 120 | 4 |
MD-1.5 | 680*1180*1870 | 1600*2000*2210 | 2150 | 50 | 150 | 4.5 |
MD-2.0 | 1000*1200*1700 | 2000*2000*2040 | 2400 | 60 | 200 | 4.5 |
Cycles
Cycle No. | Cycle Name | Further Details |
1 | Instruments/Tools |
3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. |
2 | Clothing |
3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min. |
3 | Liquid |
15 min exchange, expose temperature 121℃, expose time 15 min, cooling time 25 min. |
4 | B-D Test |
3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min. |
5 | Vacuum Leakage Test |
Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect. |
6 | User Programmable |
All preset parameters can be resettable; Multiple customized programs can be set and stored by user. |
Electrical power
Our ordinary electrical power is AC380, 50Hz, 3phase/N/E
Other electrical power standards are available and compatible
Steam feeding
Steam pressure: 0.4---0.7MPa
- External steam supply, 0.4---0.7MPa, saturated steam offer by user
- Built-in electrically heated steam generator (Chamber volume <= 600L) is optional
- Individual electrically heated steam generators or natural gas heated steam generators is optional
Water
Softened water: Hardness <50ppm, pH Neutral
Water pressure: 0.15----0.3MPa
Compressed air
Oil free compressed air is important to the autoclave’s running.
Oil free silence air-compressor is optional for user’s selection.
Compressed air pressure: 0.4---0.8MPa
Applications:
Laboratory autoclaves are used to destroy microorganisms that may be present in medical
waste before disposal in a traditional landfill.
Competitive Advantage
Sterilization autoclave provides generators a way to treat waste in a cost-efficient manner.
The destruction of the microorganisms is highly effective.
Medpharm sterilizer showing:
Contact Person: Ms. Juliet
Tel: + 86 15466171
Fax: +86-512-58592400