Product Details:
Payment & Shipping Terms:
|
Door Type: | Motorized Hinge Door | Chamber Volume: | 240 Liters To 1500 Liters |
---|---|---|---|
Chamber Material: | SUS304 | Control System: | PLC With Touch HMI |
Application: | Laboratory And Research | ||
High Light: | medical sterilizer machine,sterile medical equipment |
High Vacuum Degree Sterilizers Autoclave With Low Noise Water-ring Vacuum Pump For Silence Laboratory
Description
Medpharm offers a wide selection of saturated steam sterilizers autoclave to exceed industry standards,
available in single or pass-through versions, with hinged or sliding doors . Built to a very high standard,each unit is tailored to the customer’s individual specifications.
Medpharm is able to offer an extremely diversified product range capable of meeting the
requirements of the most varied applications and satisfy the strict standards of the Laboratory
and research.
Features
Advanced Control system
• Excellent PLC controller is provided with preprogrammed cycles to meet most laboratory requirements.
• The controller interface is designed to permit easy user access and simplified one-motion start function.
• Multiple displays are arrayed on the graphic user interface to clarify cycle selection and real-time performance through plot, detail and line graph expression.
Sterilization and Test Cycles
• Vacuum Cycles. Cycles selected for sterilization of nonliquids are programmed to force removal of ambient air trapped within the load through initiation of a vacuum sequence. Time sequencing and duration of individual phases is tailored to the preset determination.
• Liquids Cycles. Cycles selected for sterilization of vented liquids are designed to slow the rate
of exhaust to prevent boilover as chamber pressure is returned to atmospheric Pressure.
• Test Cycles. Individual test cycles are preprogrammed in accordance with standard best
practices to verify the efficacy of the sterilizer and its performance.
• Bowie-Dick Test. The Bowie-Dick test is a widely accepted process to assure that ambient air has been properly removed from the chamber and load, prior to sterilization.
• Vacuum Leak Test. The integrity of the sterilizer chamber and associated plumbing, both
under pressure and vacuum, is verified by running a vacuum leak test as directed by local lab
safety or facilities management officers.
Main parameters
►Max working pressure: 0.23MPa
►Max working temperature: 134℃
►Temperature even: ≤±1℃
►Soften water: 0.15---0.3MPa
►Steam: 0.4---0.8MPa
►Compressed air: 0.4---0.8MPa
Model |
Chamber Size |
Overall Size |
Steam |
Water |
Power |
W*H*D mm |
W*H*D mm |
Kg/cycle |
Kg/cycle |
KVA |
|
MDL-0.24 |
600*600*670 |
1500*1800*1010 |
20 |
30 |
2 |
MDL-0.36 |
600*600*1000 |
1500*1800*1340 |
25 |
40 |
2 |
MDL-0.6 |
610*910*1170 |
1500*1900*1510 |
30 |
60 |
3 |
MDL-0.8 |
610*910*1450 |
1500*1900*1790 |
35 |
80 |
3 |
MDL-1.0 |
680*1180*1250 |
1600*2000*1590 |
40 |
100 |
4 |
MDL-1.2 |
680*1180*1500 |
1600*2000*1840 |
45 |
120 |
4 |
MDL-1.5 |
680*1180*1870 |
1600*2000*2210 |
50 |
150 |
4.5 |